Petsafe DRINKWELL HY-DRATE PFD17-12901 User Manual

Browse online or download User Manual for For pets Petsafe DRINKWELL HY-DRATE PFD17-12901. Petsafe DRINKWELL HY-DRATE PFD17-12901 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Thank you for choosing the PetSafe
®
brand. You and your pet deserve a companionship that includes memorable moments and a shared understanding together. Our products and training tools
promote a lifestyle of protection, teaching, and love—essentials that influence memories for a lifetime. If you have any questions about our products or training your pet, please visit our website at
www.petsafe.net or contact our Customer Care Center at 1-800-732-2677.
PRODUCT WARRANTY
To get the most protection out of your one-year warranty, please register your product within 30 days at www.petsafe.net. By registering and keeping your receipt, you will enjoy the product’s
full warranty and should you ever need to call the Customer Care Center, we will be able to help you faster. Most importantly, PetSafe
®
will never give or sell your valuable information to anyone.
Complete warranty information is available online at www.petsafe.net.
DRINKWELL
®
hy·drate
, Pet H
2
O Filtration System
Model Numbers: PFD17-12901, PFD17-12902, PFD17-12903, PFD17-12904,
PFD17-12899, PFD17-12900
INSTRUCTIONS PERTAINING TO; RISK OF FIRE, ELECTRIC SHOCK
OR HARM TO PERSONS
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
When using electric appliances, basic precautions should always be followed,
including the following:
• Readalltheinstructionsbeforeusingappliance.
• Toreducetheriskofinjury,closesupervisionisnecessarywhenan
applianceisusednearchildren.
• Onlyuseattachmentsrecommendedorsoldbythemanufacturer.
• Donotuseoutdoors.INTENDEDFORINDOORHOUSEHOLD
USEONLY.
• Donotunplugbypullingonthecord.Tounplug,grasptheplug,not
thecord.
• Donotoperateanyappliancewithadamagedcordorplug,orafterthe
appliancemalfunctionsorisdroppedordamagedinanymanner.Return
appliancetothenearestauthorizedservicefacilityforexamination,repair,
orelectricalormechanicaladjustment.
• Foraportableappliance–Toreducetheriskofelectricalshock,donot
placeorstoreappliancewhereitcanfallorbepulledintoatuborsink.
• Alwaysunpluganyappliancewhennotinuse,beforeputtingonortaking
offparts,andbeforecleaning.Neveryankacordtoremovefrom
theoutlet.
• Donotcontactmovingparts.
• Alwayspositionpowercordsoutofthewayoffoottrafctoavoidtripping.
• Donotallowyourpettochewonthepowercordorhy·drate
product.
• IftheACadaptergetswet,turnoffelectricitytothatoutlet.Donot
attempttounplug.
•Examinethisapplianceafterinstallation.Itshouldnotbepluggedinif
thereiswateronthecordorplug.Toavoidthepossibilityoftheplug
oroutletgettingwet,theoutletshouldalwaysbeabovethelevelof
thehy·drate
.
•DonotsubmerseACpoweradapterintowater.
Radio Systems
®
Corporation·10427ElectricAvenue·Knoxville,TN37932·1-800-732-2677·www.petsafe.net·400-1281-17/2
Setup and Operating Instructions:Beforeusingthehy·drate
, Pet H
2
O
FiltrationSystemforthersttime,itisimportantthatyouproperlyprepare
theproductforuse.Thehy·drate
includesalterthatshouldbethoroughly
rinsedtoremovethecarbonlterdust.Don’tworry;thedustisnotharmfulto
yourpet.Forsmallerbowlsyouwillndithelpfultoadjusttheowcontrolto
preventwaterfromsplashingfromthebowl.
Beginbyopeningthehy·drate
,usingyourthumbtoliftthesnaplocated
onthebacktoopentheoutershell.Notetheorientationoftheinternalparts
andthelocationoftheowcontrolonthesideofthepump (See Fig. 1a &
1c).Removethelterandrinseitunderrunningwaterforapproximately20
secondsoruntilnocarbondustisshowinginwater.Gentlyshakeexcess
waterofflterandplacebackintotheuppershell(See Fig. 1a).Closethe
hy·drate
backtogether.
Fitthehy·drate
tothebottomofyourpet’sbowlandpushdownuntilall
threesuctioncupsaresecuredtobottom.Usethesuctioncuponthepump’s
powercordtoneatlyattachcordtotheoutsideofthebowl.Fillthebowl
withwatersothehy·drate
isfullysubmerged.Thelow-voltagesubmersible
pumpissafetofullygounderwater.Attachthepump’spowercordtothe
ACadapterpowercord,dryyourhandsandplugintoastandard120voltAC
circuitoutlet.Thehy·drate
willstartandwithin20secondswaterwillow
fromthewaterowopening.Toturnoffthehy·drate
,unplugfromtheoutlet.
Somepetspreferdrinkingfromarunningsourceofwater.Tocreateawater
streameffect,maintainawaterlevelattheminimumH
2
Olevelnotedonthe
hy·drate
(See Fig. 1a).
Levelofwaterabovethehy·drate
willgivearippling
orbubblingeffectontopofthewater.Bothoptionsprovidecontinuous
movementandltrationforcleaner,fresherwater.Now,adjusttheowcontrol
onthepumpbasedonthesizeofthebowl,desiredowofwaterortoreduce
watersplatteringfromthebowl(See Fig. 1a & 1c).Afterbeginningoperation
ofthehy·drate
,simplyallowyourpettoadjustathisorherownpace.Some
petsmaytakeseveraldaysorlongertobeginuse.Afteryourpetisacclimated
tothehy·drate
,continuetoreplenishyourpet’sdrinkingwaterfrequentlyfor
maximumhydration.
Itisnotrecommendedthatanyappliancebeleftrunningunattendedfora
prolongedperiodoftimeasthewatermaygetconsumedorevaporate,thus
causingthemotortorundryandcanreducelifeofthepump.
Cleaning Instructions: The hy·drate
upper shell, lower shell with suction
cupsandpumpconnectoraredishwashersafeatlowtemperaturesorcan
behandwashedwithwarmsoapywater.THEPUMPISNOTDISHWASHER
SAFE!Toremovepumpfromuppershellpushinrubberttingtowards
pumptorelease.Threadpumppowercordthroughsuctioncuploopand
pumpcordpass-through(See Fig. 1a & 1b).Thehy·drate
pumpshouldbe
disassembledandcleanedeverytwoweeks(See Fig. 2 & 3).Toremove“hard
water”mineralbuild-upsoakdisassembledpumpinregularwhitevinegarfor
severalminutesandrinsethoroughly.Oncethepartsareclean,reassemble
thepumpbyreplacingtheimpeller,stator,owcontrol(See Fig. 4) and the
intakeplate.Threadpumppowercordbackthroughpumpcordpass-through
andsuctioncuploop,andpositionpumpontothepumpconnectorpostin
the upper shell (See Fig. 1a & 1b).Grasptherubberttingandpullthrough
hole in upper shell until it snaps into place sealing the opening (See Fig. 1a &
1b).Thelengthofthepumppowercordmayneedtobeadjustedbypulling
eitherendtopositionpumpontopumpconnectorpost.
Theltershouldbereplacedevery2-4weekstomaintainltered,freshand
cleanwater.Smallfoodparticlesandhairmustbecleanedbetweentheintake
andlterasneededtomaintainstrongcurrentow.
IMPORTANT: Warranty may be voided if pump is not cleaned regularly.
Product Specifications:
Voltage/Power Consumption 120VAC 60Hz 3.3 WATTS
12 Volts low-level power adapter output
Accessories:
Topurchasereplacementpartsoraccessories,contactPetSafe
®
Customer
Care Center at 1-800-732-2677orbyvisitingwww.petsafe.net.
ReplaceableFilters,3-pack PFD17-12905
Terms of Use and Limitations of Liability
1.TermsandUse-Thisproductisofferedtoyouconditioneduponyouracceptance
withoutmodicationsoftheterms,conditionsandnoticescontainedherein.Useof
thisproductimpliesacceptanceofallsuchterms,conditionsandnotices.
2.ProperUse-Includesreviewingthesafetyprecautionslisted.
3.NoUnlawfulorProhibitedUse-Thisproductisdesignedforpetsonly.Thisdeviceis
notintendedtoharm,injureorprovokeyourpet.Usingthisproductinawaythatis
notintendedcouldresultinviolationofFederal,Stateorlocallaw.
4.LimitationsofLiability-InnoeventshallRadioSystems
®
Corporation be liable for any
direct,indirect,punitive,incidental,specialorconsequentialdamageswhatsoever
arisingoutoforconnectedwiththeuseormisuseofthisproduct.Buyerassumesall
risksandliabilitiesfromtheuseofthisproduct.
5.ModicationsofTermsandConditions-RadioSystems
®
Corporationreservesthe
righttochangetheterms,conditionsandnoticesunderwhichthisproductisoffered.
Withyourthumbandforenger,
gentlysqueezethesidesof
intakeplate,andpulloff.
Removetheowcontrol,stator
andimpeller.Toremoveimpeller
useangernailtoliftout;itis
heldinmagnetically.
Replaceowcontrolby
placing post into opening
onthepumpmotor.Align
owcontrolknobto
openingonintakeplate
andattachintakeplate
topump.
Fig. 4
Cleanwithwarmsoapy
water.Useacottonswab
orasmallcleaningbrush
togetintothemotor
cavityandremoveany
build-up.
Fig. 2
Pump
Impeller
Stator
Flow
Control
Intake Plate
Fig. 3
Page view 0
1

Summary of Contents

Page 1 - DRINKWELL

Thank you for choosing the PetSafe® brand. You and your pet deserve a companionship that includes memorable moments and a shared understanding togethe

Comments to this Manuals

No comments